Gfci receptacle outlets electrical question.
Gfci required in laundry room.
According to the nec a gfci is required if the power outlet is within 1 8 meter radius from the water source.
Gfci receptacles monitor any electric current imbalance between the circuit s hot and neutral conductor and shuts of the circuit if an imbalance is present.
Because by definition where the washing machine is located becomes the laundry the two phases of this requirement meant that initially a washing.
If the laundry room does not have a window then an exhaust fan will be required along with a switch.
The nec doesn t require gfci protection for clothes washing machines specifically but it does for laundry areas.
The only wiggle room for the washing machine is if it drains into a standpipe drain and there is no sink.
The requirement for afci protection in kitchens and laundry areas as well as for branch circuit extensions or.
The requirement for gfci protection in laundry areas was deleted.
2005 does require gfci 6 from laundry sinks.
It s a device that protects people from receiving shocks from faults in an electrical system.
A laundry room needs at least one 20 amp circuit for receptacles serving laundry equipment.
Now let s refer to nec 2017 section 210 8 for the answer to the gfci portion of our question.
Otherwise you probably need a a new washing machine or you will be fixing you old one so it runs on a gfci.
Although the code does not specifically state that a washing machine receptacle has to be gfci the washing machine must have water service and a drain so its location becomes defined as a laundry.
Yes as of the 2017 edition of the national electrical code nec any receptacles in a laundry room must be gfci protected.
Receptacles within 6 feet of a laundry sink were first required to be gfci protected by the 2005 edition of the national electrical code nec.
An electric dryer needs its own 30 amp 240 volt circuit wired with four conductors older circuits often have three conductors.
This circuit can supply a clothes washer or a gas dryer.
The code mandate was later expanded to include any receptacles in a laundry room in the 2014 nec.
Where gfci protectio n is required.
Gfci stands for ground fault circuit interrupter.
Occupancy controlled lighting will be required too.
210 8 a 10 all 125v 15a and 20a receptacles installed in laundry areas shall have gfci protection.
See the nec code requirements in the table below for more specific information.
Gfci receptacles are required in bathrooms garages crawl spaces basements laundry rooms and areas where a water source is present.
If the water supply is permanently connected to washing machines in a laundry area does it require a class a gfci protected receptacle.